- Platform
- Windows desktop application, 64-bit (x64). Installs per user; .ep3 files open in EP3.
- EnergyPlus
- Versions 23.1, 23.2, 24.1, 24.2, 25.1, 25.2, 26.1 and 26.2. New models start in 26.2, and a model can change version at any time without losing its inputs.
- EnergyPlus installation
- Install the versions you use, free, from energyplus.net. EP3 finds them and runs each model in its own version.
- Simulation
- Runs on your computer with EnergyPlus. Several runs go in parallel, on up to 75% of your processor cores.
- Internet
- Needed to sign in to your EP3 account. Map lookups and cloud AI are optional and off until you turn them on.
- Model file
- One .ep3 file holds the base model and every EEM.
- Reference
- The EnergyPlus 26.2 Input Output Reference and Engineering Reference are built in and work offline, opened from any object or field.
Want EP3 on a Mac? Tell us. · EnergyPlus versions in the handbook →
File formats
- EnergyPlus models
- Import IDF, expanded IDF and epJSON, with HVAC, from any supported version. Several files can be imported as one model with one EEM each, and an edited export can be merged back.
- EnergyPlus export
- epJSON for the base model or any EEM, ready to run in EnergyPlus.
- EP3 models and templates
- .ep3 models, and .ep3 templates from shared library folders: internal loads, constructions, HVAC systems, service hot water and EEMs.
- Drawings
- DXF, DWG (through the free ODA File Converter), PDF as line work or as an image to trace, and images. Floors come from CAD line work; windows come from coloured elevation images.
- Maps and photos
- Building outlines and heights from OpenStreetMap; GeoJSON and KML outlines; photos and scans straightened with pins.
- Weather
- EPW weather files, with DDY design days imported alongside.
- Measured data
- Meter data and utility bills from CSV or Excel, for calibration.
- Results
- EnergyPlus's own output files for every run, time series to CSV, charts to PNG, and compliance documentation as HTML or Excel.
Code compliance generators
One button generates compliance models starting with the Energy Efficiency Measure (EEM) of your choice. EP3 builds and simulates the required models and produces documentation. Need to customize the baseline? You can: it's generated as a normal EEM in EP3. Make your changes and generate the documentation again.
ASHRAE 90.1 Appendix G (Performance Rating Method)
90.1-2016, 2019 and 2022
For LEED v4.1 and v5.
- Proposed and Baseline EEMs built from your design
- Baseline HVAC Systems 1–13 selected by building type, area, floors and climate zone, with the exceptions
- Baseline envelope, lighting, receptacle and service water heating; plant sizing on coincident peaks; Baseline fan power
- Baseline simulated at 0°, 90°, 180° and 270° and averaged, unless the site fixes the orientation
- Unmet hours checked against the 300-hour limit, with warm-up and sizing adjustments tried for you
- 2022: semiheated spaces, Appendix J chiller curves, renewable energy credit and the updated tables
- Performance cost index and target, messages and action items
- Automatic documentation for LEED and code compliance submissions: EP3's Appendix G documentation in IP or SI units, and the ASHRAE 90.1 Performance-based Compliance Form (Excel 2019 or later, macros enabled)
Energy Cost Budget Method
Section 11 (90.1-2016 and 2019) · Section 12 (90.1-2022)
- Proposed and Budget EEMs built from your design
- Budget envelope, lighting and service water heating from Table 11.5.1
- All 11 budget HVAC systems of Table 11.5.2-1, from EP3's library
- Rotations only when the fenestration orientation test calls for them
- 2022: energy credits, required photovoltaics and the envelope backstop checklist
- Design energy cost against the energy cost budget, with an unmet-hours check
- Fills the ASHRAE 90.1 compliance form; totals checked against it to the cent for 2016 and 2019
What you provide
Climate zone and weather file, building segments, space classifications, energy rates (or EIA state averages), and the documentation inputs and narratives. Items that need an engineer's judgement, such as laboratory and kitchen exceptions or the exterior lighting zone, are listed as action items.
EP3 also calculates ETTV and RTTV under the BCA guidelines and shows them on the 3D model.
Modeling
Every EP3 model is an EnergyPlus model, built from EnergyPlus objects with their fields and defaults. EP3 keeps names, nodes and branches consistent as the model grows.
Geometry
Draw floors and Spaces with walls, roofs, ground contact and constructions kept up to date as you edit. Pitched roofs and dormers, windows by exposure or painted on, overhangs, fins and insets, site shading, floor multipliers and linked floors that share one plan.
Drawings and maps
Trace floor plans from CAD or PDF, place windows from elevations, and bring in neighbouring buildings from maps.
Envelope
Construction libraries for ASHRAE 90.1-2022 and the Appendix G Baseline by climate zone, with the ASHRAE Handbook of Fundamentals materials. Fill every construction slot from a library in one step.
Loads and schedules
Space Types and Zone Types carry people, lighting, equipment, ventilation and thermostats. Libraries include NECB space types and 90.1 space-by-space and whole-building occupancy types.
HVAC
Air loops, plant and condenser loops and zone equipment on a live diagram, with EP3 writing every node, branch and connector. Templates for VAV reheat, DOAS, packaged VAV, fan coil, PSZ, PTAC/PTHP, VRF, baseboard and water-source heat pump systems.
Service hot water and renewables
Mixed and stratified tanks, heat pump water heaters, solar water heating and thermal storage. PVWatts and detailed photovoltaic generators with inverters and load centers.
Energy efficiency measures
Each EEM stores only its changes and can build on others. Change the base model and every EEM follows. Branching EEMs run every combination; disaggregation splits an EEM’s savings by change.
Utility costs
Flat, time-of-use, seasonal and tiered tariffs with demand charges and ratchets, several per meter, and different tariffs in different EEMs.
Results
Tabular reports side by side, time series, node values on the HVAC diagram, results coloured on the 3D building, energy flow Sankey diagrams and parallel coordinates across EEMs.
Unmet hours
Which zones miss setpoint, when, and what they have in common, with a typical-day profile of setpoints, temperature, occupancy and HVAC operation.
Calibration
Load meter data or bills and see the ASHRAE Guideline 14 fit. EP3 can adjust the model to match the measurements.
Quality checks
A model validation dialog, an error viewer that leads to the object at fault, and checks for unexpected surface adjacencies.
Atlas, the AI assistant
- Cloud models
- Anthropic (Claude), OpenAI (GPT) or Google (Gemini) with your own API key, billed by the provider with no markup. Keys are stored encrypted on your computer.
- Local models
- LM Studio or Ollama on your computer, set up by a wizard that checks your hardware. Nothing is sent to an AI provider.
- Access levels
- Off, Help (handbook and attached files only), Analysis (reads the model and results) or Full (proposes changes, creates EEMs and runs simulations). Saved with each model; new models start at Off.
- Your approval
- Proposed changes arrive as a card you integrate or reject, and one Undo reverts them.
- Privacy
- Atlas reads only what it needs, never the whole model. Incognito mode replaces project, zone and object names with placeholders.
- Attachments
- Excel, CSV, PDF and images, such as envelope schedules and equipment submittals.
Validation
EP3 imports were checked against 97 ASHRAE Standard 140 (BESTEST) models and 3,860 outputs: 95.7% match the originals at R² ≥ 0.99. How we validate EP3 →
Licensing and teams
- Licences
- Per-seat licences, or floating seats shared across a team.
- Shared libraries
- Point EP3 at shared library folders and every modeler starts from the same constructions, loads, HVAC systems and EEMs.
- Trial
- Request a trial